IMPERIAL OIL CO.,INC. -- GEAR OIL, 80W-90 -- 9150-01-035-5394
=====================  Product Identification  =====================

Product ID:GEAR OIL, 80W-90
MSDS Date:03/16/1998
FSC:9150
NIIN:01-035-5394
=== Responsible Party ===
Company Name:IMPERIAL OIL CO.,INC.
Address:ORCHARD PLACE
Box:279
City:MORGANVILLE
State:NJ
ZIP:07751
Country:US
Info Phone Num:732-591-9400
Emergency Phone Num:732-591-9400
Preparer's Name:PAUL LEWICKI
CAGE:58563
=== Contractor Identification ===
Company Name:IMPERIAL OIL CO INC
Address:FOOT OF ORCHARD PL
Box:279
City:MORGANVILLE
State:NJ
ZIP:07751
Country:US
Phone:732-591-9400/FAX: 732-591-8825
Contract Num:SP0450-99-M-B145
CAGE:58563
Company Name:NAUGHTON ENERGY CORP
Address:RT 940
Box:709
City:POCONO PINES
State:PA
ZIP:18350-0709
Country:US
Phone:570-646-0422
Contract Num:SP0450-98-D-4041
CAGE:1DL10

=============  Composition/Information on Ingredients  =============

Ingred Name:LUBE OIL BASE STOCK/MINERAL OIL, SOLVENT REVFINED HEAVY
    PARAFFINIC, SEVERELY HYDROTREATED
CAS:64741-88-4
RTECS #:PY8040501
Minumum % Wt:93.
Maxumum % Wt:96.
Other REC Limits:NONE RECOMMENDED
OSHA PEL:5 MG/M3 (OIL MIST)
ACGIH TLV:5 MG/M3 (OIL MIST)

Ingred Name:PROPRIETARY ADDITIVES (FROM LUBRIZOL CORP.)
Minumum % Wt:4.
Maxumum % Wt:7.
Other REC Limits:NONE RECOMMENDED

=====================  Hazards Identification  =====================

Routes of Entry: Inhalation:YES  Skin:NO  Ingestion:NO
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:IF PROLONGED CONTACT WITH THIS
    MATERIAL IS REQUIRED IN A CONFINED AREA AND/OR THE MATERIAL HAS
    BEEN HEATED, A GAS MASK OR OTHER SUITABLE BREATHING APPARATUS
    SHOULD BE WORN.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:IN CASE OF SKIN CONTACT, WASH WITH DETERGENT
    AND HOT WATER.
Medical Cond Aggravated by Exposure:PRE-EXISTING PULMONARY AND
    RESPIRATORY CONDITIONS WILL BE AGGRAVATED BY INHALATION OF THE
    FUMES AND/OR MIST.

=======================  First Aid Measures  =======================

First Aid:IF SWALLOWED, DO NOT CAUSE VOMITING. IF PERSON IS CONSCIOUS,
    REMOVE TO FRESH AIR AND GET MEDICAL HELP. NEVER ATTEMPT TO
    ADMINISTER ANYTHING BY MOUTH TO AN UNCONSCIOUS PERSON

=====================  Fire Fighting Measures  =====================

Flash Point Method:COC
Flash Point:=200.C, 392.F
Extinguishing Media:CARBON DIOXIDE, WATER FOG, FOAM OR DRY CHEMICAL.
Fire Fighting Procedures:WEAR MESA/NIOSH APPROVED SELF CONTAINED
    BREATHING APPARATUS AND EYE PROTECTION. (SCHEDULE 13) USE WATER
    SPRAY TO COOL FIRE EXPOSED CONTAINERS AND TO PROTECT PERSONNEL.
Unusual Fire/Explosion Hazard:FUMES, SMOKE, OXIDES OF SULFUR, OXIDES OF
    NITROGEN AND CARBON MONOXIDE.

==================  Accidental Release Measures  ==================

Spill Release Procedures:CONTAIN AND DIKE WITH INERT MATERIAL ( FULLERS
    EARTH, SAND, OIL ABSORBENT, ETC.) PREVENT MATERIAL FROM GETTING
    INTO SEWERS AND OPEN BODIES OF WATER. PUT SPILLED MATERIAL INTO
    DRUMS FOR SUITABLE CONTAI NERS.
Neutralizing Agent:NOT PROVIDED

======================	Handling and Storage  ======================

Handling and Storage Precautions:DO NOT HEAT ABOVE 140F. OPEN
    CONTAINERS SHOULD BE STORED IN A WELL VENTILATED AREA AND ALWAYS
    FROM OPEN FLAMES.
Other Precautions:CONTAMINATED CLOTHING SHOULD BE REMOVED AND LAUNDERED
    BEFORE RE-USE. SATURATED SHOES SHOULD BE DISCARDED.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:IF LONG TERM EXPOSURE TO VAPORS IS ANTICIPATED,
    AN APPROVED AIR RESPIRATOR SHOULD BE USED, PARTICULARLY IN A
    CONFINED AND/OR THE MATERIAL HAS BEEN HEATED.
Ventilation:SPECIAL: AS NOTED ABOVE.
Protective Gloves:IMPERVIOUS.
Eye Protection:SPLASH GOGGLES.
Other Protective Equipment:NOT PROVIDED
Work Hygienic Practices:NO SPECIAL HYGIENIC MEASURES ARE NECESSARY.
Supplemental Safety and Health

==================  Physical/Chemical Properties  ==================

HCC:V6
NRC/State Lic Num:NOT RELEVANT
Boiling Pt:=315.6C, 600.F
Vapor Pres:1MM/ @ 68F
Vapor Density:<1
Spec Gravity:0.8990
Evaporation Rate & Reference:<1 (N-BUTYL ACETATE=1)
Solubility in Water:0 %
Appearance and Odor:AMBER COLOR - PROPANE ODOR

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS, ACIDS,  ALKALIS.
Stability Condition to Avoid:DO NOT HEAT ABOVE 140F.
Hazardous Decomposition Products:HYDROGEN SULFIDE.
Conditions to Avoid Polymerization:OPEN FLAMES, PARTICULARLY IN
    CONFINED SPACES OR NON-VENTILATED AREAS.

===================  Toxicological Information	===================

Toxicological Information:BASED UPON AVAILABLE DATA AND TECHNOLOGY, THE
    LUBRICANT DESCRIBED HEREIN IS NOT CONSIDERED TO BE TOXIC OR
    CARCINOGENIC TO HUMANS.

=====================  Ecological Information  =====================

Ecological:NOT PROVIDED

====================  Disposal Considerations  ====================

Waste Disposal Methods:IN ACCORDANCE WITH LOCAL, STATE AND FEDERAL
    REGULATIONS CONCERNING HAZARDOUS WASTE DISPOSAL.

===================  MSDS Transport Information  ===================

Transport Information:NOT PROVIDED

=====================  Regulatory Information  =====================

SARA Title III Information:NOT PROVIDED
Federal Regulatory Information:NOT PROVIDED
State Regulatory Information:NOT PROVIDED

=======================  Other Information  =======================

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.