FLAIR INDUSTRIAL AIR DIVISION -- ACTIVATED CARBON -- 6810-00-128-8031
=====================  Product Identification  =====================

Product ID:ACTIVATED CARBON
MSDS Date:10/01/1994
FSC:6810
NIIN:00-128-8031
=== Responsible Party ===
Company Name:FLAIR INDUSTRIAL AIR DIVISION
Address:344 CHURCHMANS RD
Box:667
City:NEW CASTLE
State:DE
ZIP:19720
Country:US
Info Phone Num:302-328-1345
Emergency Phone Num:800-424-9300 (CHEMTREC)
CAGE:IO422
=== Contractor Identification ===
Company Name:FLAIR INDUSTRIAL AIR
Address:344 CHURCHMANS RD
Box:667
City:NEW CASTLE
State:DE
ZIP:19720
Country:US
Phone:302-328-1345
CAGE:IO422
Company Name:FLAIR INDUSTRIAL AIR DIVISION
Box:UNKNOW
CAGE:FLAXR

=============  Composition/Information on Ingredients  =============

Ingred Name:CARBON
CAS:7440-44-0
RTECS #:FF5250100
Fraction by Wt: 100%
OSHA PEL:N/K 
ACGIH TLV:N/K 

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:YES
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:ACUTE: EYES: CAN CAUSE IRRITATION.
    SKIN: CAN CAUSE IRRITATION. INGESTION: CAN CAUSE IRRITATION OF THE
    MOUTH, THROAT AND STOMACH. INHALATION: CAN CAUSE IRRITATION OF THE
    NOSE AND LUNGS. CHRONIC: NONE S PECIFIED BY MANUFACTURER.
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

=======================  First Aid Measures  =======================

First Aid:EYES: WASH WITH WATER FOR 15 TO 20 MINUTES. SEEK MEDICAL
    ATTENTION IF NECESSARY. SKIN: WASH WITH SOAP AND WATER FOR 5
    MINUTES. INGESTION: SEEK MEDICAL ATTENTION IF NECESSARY.
    INHALATION: MOVE PERSON T O FRESH AIR. SEEK MEDICAL ATTENTION.

=====================  Fire Fighting Measures  =====================

Extinguishing Media:WATER, DRY CHEMICAL OR CARBON DIOXIDE.
Fire Fighting Procedures:WEAR NIOSH APPROVED SCBA & FULL PROTECTIVE
    EQUIPMENT .
Unusual Fire/Explosion Hazard:FLAMMABLE SOLID - CARBON DOES NOT SUPPORT
    FLAME BUT RATHER GLOWS AS CHARCOAL.

==================  Accidental Release Measures  ==================

Spill Release Procedures:SWEEP UP INTO SUITABLE CONTAINER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:CAUTION! WET ACTIVATED CARBON REMOVED
    OXYGEN FROM AIR CAUSING SEV HAZ TO WORKERS INSIDE CARBON VESSELS &
    ENCLOSED/CONFINED SPACES.
Other Precautions:BEFORE ENTERING SUCH AREA, SAMPLING & WORK PROC FOR
    LOW OXYGEN LEVELS SHOULD BE TAKEN TO ENSURE AMPLE OXYGEN
    AVAILABILITY, OBSERVING ALL LOC, STATE & FED REGS. FOR MORE INFO
    CONT INDUS HYGIENIST/SFTY  OFFICER AT YOUR WORKSITE OR (SUP DAT)

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:USE NIOSH APPROVED DUST MASK IF NECESSARY.
Ventilation:ADEQUATE VENTILATION.
Protective Gloves:RUBBER GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:EMERGENCY EYEWASH AND DELUGE SHOWER MEETING
    ANSI DESIGN CRITERIA .
Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING.
Supplemental Safety and Health
OTHER PREC: THE NEW YORK STATE DEPARTMENT OF HLTH, BUREAU OF TOX
    SUBSTANCES ASSESSMENT, EMPIRE STATE PLAZA, TOWER BLDG, ALBANY, NEW
    YORK 12237.

==================  Physical/Chemical Properties  ==================

Boiling Pt:B.P. Text:4000F,2204C
Vapor Pres:1
Spec Gravity:0.27-0.32
Solubility in Water:INSOLUBLE
Appearance and Odor:BLACK, NO ODOR, GRANULE, PELLET/POWDER

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZERS SUCH AS OZONE, LIQUID OXYGEN, CHLORINE, PERMANGANATES,
    ETC.
Stability Condition to Avoid:HEAT AND SOURCES OF IGNITION.
Hazardous Decomposition Products:MAY FORM THE TOXIC GASES CARBON
    MONOXIDE AND CARBON DIOXIDE WHEN BURNED.

====================  Disposal Considerations  ====================

Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH ALL FEDERAL, STATE
    AND LOCAL REGULATIONS. ACTIVATED CHARCOAL ITSELF IS NON-TOXIC,
    HOWEVER, OTHER CHEMICALS MAY BE PRESENT THAT MAY HAVE TO BE
    CONSIDERED IN DISPOSAL.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.